Specimen Stability (for laboratory use only)
Collection Container
Sterile screw-capped container
Collection Instructions:
1. Indicate whether CSF is collected from a shunt.
2. Collect at least 1ml of CSF in a sterile screw-capped container, if possible.
3. Obtain 3 Containers, and label the containers as #1, #2 and #3.: #1 will contain CSF drawn at the start, #2 the middle part, #3 the end of collection.
4. Preferred: #3 container, as #1 container is most likely to contain contaminants.
5. Acceptable: #1 or #2 container (if #3 is unavailable).
6. Send specimen to the laboratory immediately via Porter. Do not use the pneumatic tube system.
2. Collect at least 1ml of CSF in a sterile screw-capped container, if possible.
3. Obtain 3 Containers, and label the containers as #1, #2 and #3.: #1 will contain CSF drawn at the start, #2 the middle part, #3 the end of collection.
4. Preferred: #3 container, as #1 container is most likely to contain contaminants.
5. Acceptable: #1 or #2 container (if #3 is unavailable).
6. Send specimen to the laboratory immediately via Porter. Do not use the pneumatic tube system.
Unacceptable Conditions:
CSF in preservative.
CSF in blood culture bottles.
CSF in blood culture bottles.
Specimen Stability:
Ambient
4 hours.
Reflex Tests:
N.A.
Performance
Turn Around Time:
3 - 4 days
Days Test Performed:
Testing Laboratory:
Woodlands Hospital Laboratory Medicine and Pathology, Medical Microbiology
Clinical & Interpretative
Description:
Diagnosis of Meningitis.
Methodology:
Conventional culture with direct Gram stain of specimen.
Reference Interval:
No aerobic and anaerobic bacterial growth.
Critical Values:
Requesting clinician/location will be informed of positive result.