Specimen Stability (for laboratory use only)
RAS%20container.png
Collection Container
RAS container
Specimen Type:
Random fresh urine
Minimum Specimen Volume:
10 mL
Collection Instructions:
Early morning urine is preferred.

1. Refer to https://www.wh.com.sg/labs/Specimens/Pages/Specimens-Collection.aspx for collection of urine.
2. Collect midstream urine in RAS container
3. Send specimen to the laboratory immediately.
Unacceptable Conditions:
Less than 10 mL
Specimen Stability:
Ambient
Send specimen to the laboratory immediately.
Keep refrigerated if not sent immediately.
Add on Test:
No add test
Reflex Tests:
N.A.
Remarks:

Related Formula:
Albumin: Creatinine Ratio Urine (ACR) (mg/g):
Albumin Urine (ALBU) (mg/L) / (Creatinine Urine (CREU) (mmol/L) X
0.113)

Albumin: Creatinine Ratio Urine (ACR) (mg/mmol):
Albumin Urine (ALBU) (mg/L) / (Creatinine Urine (CREU) (mmol/L)
Performance
Turn Around Time:
1 working day
Days Test Performed:
Testing Laboratory:
Woodlands Hospital Laboratory Medicine and Pathology, Biochemistry
Clinical & Interpretative
Description:
Panel includes the following tests:
• Albumin, Urine, Random
• Creatinine, Urine, Random
• Albumin:Creatinine Ratio, Urine (calculated value)

Test is useful as a risk factor for renal impairment.
Methodology:
See individual test listings.
Reference Interval:
Microalbuminuria:
Male: >2.5 - 30 mg/mmol
Female: >3.5 - 30 mg/mmol

Macroalbuminuria:
>30 mg/mmol

Monitor with Urine PCR if Urine ACR >30 mg/mmol.
Critical Values:
N.A.