Specimen Stability (for laboratory use only)
Collection Container
Green top (lithium heparin)
Service Code:
Service code pending
Collection Instructions:
Submit one of the following: Blood, bone marrow aspirate OR effusion fluid.
For blood collection:
1. Draw sufficient blood into 2 green top tubes.
2. Gently invert the tubes 8 - 10 times.
3. Send specimen to the laboratory immediately.
For bone marrow aspirate / effusion fluids collection:
1. Collect bone marrow aspirate into green top tube.
2. Gently invert the tube 8 - 10 times.
3. Send specimen to the laboratory immediately.
Refer to testing laboratory test catalogue for more information:
https://www.sgh.com.sg/patient-care/specialties-services/chromosome-analysis-of-bone-marrow-bone-core-hematologic-disorders-blood-effusion-fluid
For blood collection:
1. Draw sufficient blood into 2 green top tubes.
2. Gently invert the tubes 8 - 10 times.
3. Send specimen to the laboratory immediately.
For bone marrow aspirate / effusion fluids collection:
1. Collect bone marrow aspirate into green top tube.
2. Gently invert the tube 8 - 10 times.
3. Send specimen to the laboratory immediately.
Refer to testing laboratory test catalogue for more information:
https://www.sgh.com.sg/patient-care/specialties-services/chromosome-analysis-of-bone-marrow-bone-core-hematologic-disorders-blood-effusion-fluid
Unacceptable Conditions:
N.A.
Specimen Stability:
Ambient
Send specimen to the laboratory immediately
Performance
Turn Around Time:
14 - 21 days
Days Test Performed:
Testing Laboratory:
Singapore General Hospital (SGH), Cytogenetics
Clinical & Interpretative
Description:
Useful analysis for acute Leukaemia, lymphoma, Myelodysplastic Syndromes, Chronic Myeloid Leukaemia and other Lymphoproliferative Disorders
Methodology:
24-hour and 48-hour or 72-hour cultures. A stimulated culture is set up for LPD and multiple myeloma (MM).
Reference Interval:
See laboratory report
Critical Values:
N.A